This present manual refers to the Maxiroll and Maxicart portable filtration units. It includes important information concerning the installation, usage and maintenance of your units. Read this manual thoroughly and apply the directives and procedures. Staff and personnel using the system will have to trained on safety measures and maintenance. Since 1952, Duro Dyne Corporation has evolved into the leading manufacturer of sheet metal accessories and equipment for the heating, ventilating, and air conditioning industry. We offer sheet metal contractors and HVAC installers the widest variety of products specific to their trade.
The Dyna-Fresh!®model AQC-1 is a Control Panel with a 24 volt clock timer coordinated to work with an SRRD or SPRD round damper, for an intake of fresh air and exhaust of stale air. 4 Position Dampers can be closed, 1/3 open, 2/3 open or full open for Fresh Air and Economizer applications. The AQC-1 Air Quality Control Center, item #35220. Programmable 24-hour, 15 minute interval timer. Eliminates use of low voltage transformer for fresh air damper. Controls a 24 or 110 volt damper. See AQC-1 Specifications. 4 Position Dampers. All DuroZone Zoning Dampers, (RD, MS and MB series), are available with a 4 position motor.
CONSTANT ENERGY CONSERVATIONemphasis and local building code changes over the past several years haveresulted in efforts to make buildings and homes more weather tight and draftfree. While these efforts have been successful, eliminating outside air leakagehas created another potential problem; air quality of the interior atmosphere.
Many provincial and local governmentshave become concerned that the relatively stagnant indoor air is showingincreasing levels of carbon monoxide and carbon dioxide. Many provinces haverequired periodic introduction of outdoor air into the indoor environment. The Dyna-FreshAir Quality Control Center coupledwith a model NSPRD024 or SPRD110 Spring-Return Damper was designed for thispurpose.
- Fresh air is drawn in from the outside and mixed with return air to be distributed by the air handling equipment.
- The Dyna-FreshAQC Control Panel coordinates the blower, exhaust fan and damper to introduce fresh air and remove stale air at user selectable 15 minute intervals.
- Stale air is exhausted by the independent exhaust fan.
CONTROL CENTER
Duro Dyne Model Aqc-1 Manual Instructions
The Dyna-FreshAQC has a programmable (in 15 minuteintervals) 24 hour timer which is wired to control a DuroZoneSpring-Return Damper (110 volt or 24 volt), an exhaust fan, and the air handlerfan. Once the timer has been programmed, a call from the Dyna-FreshAQC for fresh air will:
- Open the Spring-Return Damper to allow fresh air into the return duct
- Turn on the air handler fan to distribute the fresh air into the home
- Activate an exhaust fan to remove the stale air in the home or office
Dyna-FreshAQC Air Quality Control Center
Duro Dyne Model Aqc-1 Manual
- Listed to UL and CSA Standards for Safety
- 24 Hour Clock Timer
- Programmable in 15 Minute Intervals
- Controls Either a 24 Volt or 110 Volt Damper
- Eliminates the Need for a Low Voltage Transformer to Power the Fresh Air Damper
- Installs Quickly
- Compact Design
- Manual Override Switch for Continuous Fresh Air